Adjusted power
Motion detector
Power variation with movement detector
Pre-requisites
Luminaires with programmable electronic driver using DETECT option
Limits
Minimal power 16% – Timing from 30s to 1h30
Street light height between 4 and 6m
Turning off of the luminaire not possible
Connection to other functions possible
BP8 or BP6 program – P-Adjust – F-Constant
Performance
Allows lighting variation according to detection
The captor is installed on the luminaire
Default timing 3mn
30% threshold without detection. 100% threshold with detection
Motion detector characterictics
Detection distance: 10m max
Detection zone: 80 zones
Target speed of movement: 1.2 to 5.4km/h
Target size: human body, i.e 700 x 250mm
P-Adjust
Adjust the lighting for optimal display
Pre-requisites
Luminaires with programmable electronic drivers using P-Adjust programs
Limits
Minimal power 16%
Connection to other functions possible
Color Cycle program – Var – F-Constant
Performance
Allows to adjust the LED power of a luminaire from 5 to 5W
Example: P-Adjust 70W is a 94W module adjusted to 70W power
F-Constant
Power Adjustable to time
Pre-requisites
Luminaires with programmable electronic drivers using F-Constant programs
Connection to other functions possible
Color Cycle program – P-Adjust - Var
Performance
Allows to have a constant outgoing flux from the luminaire
Compensates flux depreciation of LED or the luminaire
Other SmartLum options
Point to point control
Define the correct local amount of brightness in the right place, at the right time.
Autonomous group
Ensure control of lighting points. Each point able to operate as a pilot.
Group management
Ensure control of lighting points from a grid.
Management of lighting points
Control the amount of brightness at the right place and the right time and ensure monitoring of each lighting point.